Powerful
and compact—fits into small shelves on gas kits and is an
excellent choice for updating existing anesthesia delivery systems with
state-of-the-art agent detection and proprietary 5-agent gas analysis
technology.
The Poet IQ2®
Anesthetic Gas Monitor provides an affordable solution for 5-agent gas
monitoring in any operating environment. The Poet IQ2 has an external
video output port that is compatible with VGA flat screen displays,
allowing patient data to be displayed where the surgical team needs to
see the information. The anesthetic monitor comes with an internal high
resolution color display that is designed into a compact, easy to use
control panel that can fit into tight spaces. The internal display
controls can be placed within easy reach while an external large screen
display can be mounted where ever desired.
The Poet IQ2 automatically identifies and
quantifies inspired and expired CO2,
N2O, O2,
and five anesthetic agents. The exceptional dynamic range of the
advanced High IQ™ agent detector allows the monitor to
accurately measure and display mixed gas measurements at low volumes.
The system's reliable performance, ease of use,
flexible design, and affordable cost make it the ideal monitoring
solution for anesthesia applications in hospitals and surgical centers.
|
|
 |
|
|
 |
 |
|
|
|
|
- State-of-the-art NDIR technology identifies and
measures five anesthetic agent gases:
Halothane, Isoflurane, Enflurane, Sevoflurane, and Desflurane.
- Automatic and manual primary agent detection.
- Breath-by-breath CO2,
O2, N2O
monitoring.
- Gas flow sampled at 100, 150, and 200 ml/min.
- Mixed agent identification.
- Measurement accuracy is not affected by alcohol or
metabolic ketones.
- Fast warm-up time ensures full accuracy within
minutes.
- No user calibration required; minimal user
interaction.
- Intuitive, easily configured user interface
minimizes training and is ideal for multiple users.
- Bright, real-time display of numerical values and
waveforms provides instant notification of changing patient status.
- Lightweight, portable design provides flexible
workspace options.
|
|
 |
 |
|
 |
 |
|
 |
Gas Monitoring
Method: Sidestream; Non-dispersive infra-red (NDIR)
Identified Gases: Halothane, Isoflurane, Enflurane,
Desflurane, Sevoflurane, CO2, N2O, Oxygen
Concentration Units: Vol%, Torr, kPa, mmHg
Flow Rates: 100 ml/min, 150 ml/min, 200 ml/min
Occlusion Clearing: Automatic
Auto Zeroing: Occurs 30 to 60 minutes
Duration: 3.0 to 7.0 seconds
Manual user calibration not required.
TemPerature stabilized optical assembly.
Agent Detection
Measurement Range:
Halothane: 0 to 10%
Isoflurane: 0 to 10%
Enflurane: 0 to 10%
Desflurane: 0 to 20%
Sevoflurane: 0 to 10%
CO2: 0 to 12.5%
N2O: 0 to 99%
Oxygen: 0 to 100%
Measurement Accuracy:
Agents: ± (0.1% abs. + 4% reading)
CO2: ± 0.2% abs. or
4% of reading
N2O: ± (1.5% abs. +
4% of reading)
Oxygen: ± 3 vol% (for 0-90%), ± 4 vol% (for
91-99%)
Time to Detect Agent: < 15 seconds @
200ml/min
Agent Detection Resolution: 0.1 Volume Percent
Mixed Gas Threshold: 0.2 vol. % +10% of total concentrations
Rise Time:
Agents: 450 msec
CO2: 350 msec; N2O: 400 msec; Oxygen: 600 msec
Respiration Range
Range: 1 to 60bpm
Accuracy: ± 2bpm
System Features
Display
Main Display: Active color TFT
Size: 5.9" Display Area
Resolution: Internal Display; 320 x 240 pixels
External Video; 640 x 480 pixels
Number of Traces: 3 maximum
Controls
Keys: 7; membrane-activated
Rotary knob: Push and rotate; 24 steps/turn
System Outputs
Com 2; Serial/Analog, mini-DIN8
Com Ports: Com 1; RS 232-compatible, Serial DB-9
Video Port: Color VGA compatible, High Density
D-Sub 15
Trends
Memory: 24 hours of tabular & graphic patient data
Power Requirements
Voltage: 100, 120, 220, 240 VAC; 50/60 Hz
Consumption: 40 W, typical
Mechanical
Weight: 13 lbs. (5.9 kg.)
Size: 6.5” (H) x 11.0” (W) x 12.0” (D);
16.5cm (H) x 27.94cm (W) x 30.48cm (D)
Environmental
Operating Temperature: 15º to 35º C; 59º to
95º F
Storage Temperature: -5º to 50º C; 23º to
122º F
Operating/Storage Humidity: 15% to 95%, noncondensing
Altitude: -1,000 to 10,000 ft. (-300m to 3000m)
Type of Protection: Class I Equipment
Degree of Protection: Type CF
Protection against ingress: Ordinary
Compatible with external VGA displays.
External display not included.
Specifications subject
to change without notice.

|
|
 |
 |
|
|
|
 |
GAS MONITORING ACCESSORIES
Sampling
Devices
| Catalog Number |
Description |
| 625N |
Sample Lines (Box of
25) |
| 624 |
Disposable Nasal Cannula
(Box of 10) |
| 628 |
Divided Nasal Cannula
(Box of 10) |
| 616 |
Endotracheal Adaptor, Straight
(Box of 10) |
| 617 |
Endotracheal Adaptor, Elbow (Box
of 10) |
| |
|
| 938F-NC |
WaterChek™ 2+
Water Trap (Box of 30) |
| 644 |
Replacement O2
Cell |
| 655 |
Scavenging Kit (Exhaust
Line & Adaptor) |
Calibration
Accessories
| Catalog Number |
Description |
| 621 |
Cal Gas Cylinder (5%
CO2, Balance N2) |
| 622 |
Cal Gas Cylinder (10%
CO2, Balance N2) |
| 716 |
Cal Gas Cylinder (95%
O2, Balance CO2) |
| 620 |
Cal Gas
Cylinder (100% N2) |
| 623 |
Hardware
Regulator For Cylinder |
| 613 |
Regulator
Tubing |
| 641 |
Cal Gas
Aerosol (5% CO2, Bal N2) |
| 642 |
Cal Gas
Aerosol (10% CO2, Bal N2) |
| 631 |
Cal Gas
Aerosol (1% Isoflurane, 5% CO2, 60% N2O, Bal N2) |
| 634 |
Cal Gas
Aerosol (1% Enflurane, 5% CO2, 60% N2O,
Bal N2) |
|
635
|
Cal Gas
Aerosol (1% Halothane, 5% CO2, 60% N2O,
Bal N2) |
| 1367 |
Cal Gas
Aerosol (1% Sevoflurane, 5% CO2, 60% N2O,
Bal N2) |
| 1366 |
Cal Gas
Aerosol (4% Desflurane, 5% CO2, 60% N2O,
Bal N2) |
Calibration
Kits
| Catalog Number |
Description |
| 612 |
CO2 only
(Non-Anesthetic Agent)
5% CO2 cylinder, 10% CO2
cylinder, hardware regulator with
tubing, plastic storage case. |
| 715 |
CO2 and O2 (Non-Anesthetic Agent)
5% CO2 cylinder, 10% CO2
cylinder, 95% O2 cylinder regulator
with tubing, plastic storage case. |
| 1365 |
Anesthetic Agent Verification Kit (5 Agent)
One of each five aerosol
agents, ISO, ENF, HAL, SEV, DES
as described above, includes plastic regulators with tubing. |
| 909 |
Power Cord (Domestic US) |
| 910UK |
Power Cord (United Kingdom) |
| 910INT |
Power Cord (International) |
| 910 Unterm |
Power Cord (Unterminated) |
| 603 Japan |
Power Cord (Japan) |

|
|
 |
For
immediate assistance, call our Customer Service Hotline
at 800-458-4615 - or
Contact Us to request more information.
|
|
 |
|
|
|