A powerful combination – proprietary CSI vital signs and
5-agent gas analysis technology. Versatile, reliable, and incredibly
compact. Designed to operate simply, in less time, and with greater
accuracy!
CSI’s new Poet IQ®
Gas Monitor, together with the Poet Plus®
8100 Vital Signs Monitor, provides a unique combination of leading edge
vital signs technology and anesthesia gas monitoring in a compact,
modular system. The Poet IQ automatically identifies and quantifies
inspired and expired CO2, N2O, O2,
and five anesthetic agents. The system’s reliable
performance, ease of use, flexible design, and affordable cost make it
the ideal monitoring solution for anesthesia applications in hospitals
and surgical centers.
|
 |
 |
|
|
- State-of-the-art NDIR technology identifies and
measures five anesthetic agent gases: Halothane, Isoflurane, Enflurane,
Sevoflurane, and Desflurane.
- Automatic or manual.
- Breath-by-breath O2,
CO2, and N2O
monitoring.
- Gas flow sampled at 100, 150 and 200 ml/min.
- Mixed agent identification.
- Measurement accuracy is not affected by alcohol or
ketones.
- Fast warm-up time ensures full accuracy within
minutes.
- No user calibration required; minimal user
interaction.
- Intuitive, easily configured user interface
minimizes training and is ideal for multiple users.
- Bright, real-time display of numerical values and
waveforms provides instant notification of changing patient status.
- Lightweight, portable design provides flexible
workspace options.
|
 |
 |
 |
 |
 |
Gas Monitoring
Method: Sidestream; Non-dispersive infrared (NDIR)
Identified Gases: Halothane, Isoflurane, Enflurane, Desflurane,
Sevoflurane, CO2, N2O, Oxygen
Output Data: Inspired and end-tidal gas concentrations; continuous
real-time gas concentrations; respiratory rate (elapsed time since last
breath); agent identification (primary agent and mixed agents); system
information (diagnostic status messages)
Agent Detection
Measurement Range:
Halothane: 0 to 10%
Isoflurane: 0 to 10%
Enflurane: 0 to 10%
Desflurane: 0 to 20%
Sevoflurane: 0 to 10%
CO2: 0 to 12.5%
N2O: 0 to 99%
Oxygen: 0 to 100%
Measurement Accuracy:
Agents: ± (0.1% abs. + 4% reading)
CO2: ± 0.2% abs.
or 4% of reading
N2O: ± (1.5% abs.
+ 4% of reading)
Oxygen: ± 3 vol.% (for 0-90%), ± 4 vol.% (for
91-99%)
Time to Detect Agent: < 15 seconds @ 200
ml/min
Agent Detection Resolution: 0.1 Volume Percent
Mixed Gas Threshold: 0.2 vol. % +10% of total concentrations
Rise Time:
Agents: 450 msec
CO2: 350 msec
N2O: 400 msec
Oxygen: 600 msec
Respiration Rate:
Range: 1 to 60 breaths/minute
Accuracy: ± 2 bpm or 2% of reading
System Features
System Configuration: Modular design with by-directional communication,
via cable, to the Poet Plus 8100 vital signs monitor.
Waveform Output:
Halothane, Isoflurane, Enflurane, Desflurane, Sevoflurane, CO2, N2O, O2
Concentration Units: Vol.%, Torr, kPa, mmHg
Flow Rates: 100 ml/min, 150 ml/min, 200 ml/min
Occlusion Clearing: Automatic
Auto Zeroing: Occurs 30 to 60 minutes
Duration: 3.0 to 7.0 seconds
Manual user calibration not required
Temperature stabilized optical assembly
Alarm Characteristics:
EN 475, Adjustable; with audible and visual indications from the vital
signs monitor.
Alarm Levels: High, Medium, Low, Informational
Alarm Modes: Adult/Pediatric/Neonate
High and low limit settings for each mode.
Trends: 24 hours of stored data in vital signs
monitor with graphical and tabular trends.
Power Requirements
10 to 28 VDC: 9 watts warm-up, 6 watts operational
Receives power from vital signs monitor.
Mechanical
Weight: 6.5 lbs. (2.95 kg.)
Size: 3.8” (H) x 10.4” (W) x 8.2” (D);
9.65 cm (H) x 26.4 cm (W) x 20.8 cm (D)
Environmental
Operating Temperature: 15º to 35º C; 59º to
95º F
Storage Temperature: -5º to 50º C; 23º to
122º F
Operating/ Storage Humidity: 15% to 95%, noncondensing
Altitude: -1,000 to 10,000 ft. (-300m to 3000m)
Type of Protection: Class I Equipment
Degree of Protection: Type CF, Defibrillator-proof
Protection against ingress: Ordinary
Specifications subject to change without notice.

|
 |
 |
 |
GAS MONITORING ACCESSORIES
Sampling
Devices
| Catalog Number |
Description |
|
| 625N |
Sample Lines (Box of
25) |
|
| 624 |
Disposable Nasal Cannula
(Box of 10) |
|
| 628 |
Divided Nasal Cannula
(Box of 10) |
|
| 616 |
Endotracheal Adaptor, Straight
(Box of 10) |
|
| 617 |
Endotracheal Adaptor, Elbow
(Box of 10) |
|
| 938F-NC |
WaterChek™
2+ Water Trap
(Box of 30) |
|
| 644 |
Replacement
O2 Cell |
|
| 655 |
Scavenging
Kit (Exhaust Line & Adaptor) |
|
Calibration
Accessories
| Catalog Number |
Description |
| 621 |
Cal Gas Cylinder (5% CO2, Balance N2) |
| 622 |
Cal Gas Cylinder (10% CO2, Balance N2) |
| 716 |
Cal Gas Cylinder (95% O2, Balance CO2) |
| 620 |
Cal Gas
Cylinder (100% N2) |
| 623 |
Hardware
Regulator For Cylinder |
| 613 |
Regulator
Tubing |
| 641 |
Cal Gas Aerosol (5% CO2, Bal N2) |
| 642 |
Cal Gas
Aerosol (10% CO2, Bal N2) |
| 631 |
Cal Gas
Aerosol (1% Isoflurane, 5% CO2,
60% N2O, Bal N2) |
| 634 |
Cal Gas
Aerosol (1% Enflurane, 5% CO2,
60% N2O, Bal N2) |
|
635
|
Cal Gas
Aerosol (1% Halothane, 5% CO2,
60% N2O, Bal N2) |
| 1367 |
Cal Gas
Aerosol (1% Sevoflurane, 5% CO2,
60% N2O, Bal N2) |
| 1366 |
Cal Gas
Aerosol (4% Desflurane, 5% CO2,
60% N2O, Bal N2) |
Calibration
Kits
| Catalog Number |
Description |
| 612 |
CO2 only (Non-Anesthetic Agent)
5% CO2 cylinder, 10% CO2 cylinder, hardware regulator with
tubing, plastic storage case. |
| 715 |
CO2 and O2 (Non-Anesthetic Agent)
5% CO2 cylinder, 10% CO2
cylinder, 95% O2 cylinder regulator
with tubing, plastic storage case. |
| 1365 |
Anesthetic Agent Verification Kit (5 Agent)
One of each five aerosol agents, ISO, ENF, HAL, SEV, DES
as described above, includes plastic regulators with tubing.
|
| 909 |
Power Cord (Domestic
US) |
| 910UK |
Power Cord (United
Kingdom) |
| 910INT |
Power Cord (International) |
| 910 Unterm |
Power Cord (Unterminated) |
| 603 Japan |
Power Cord (Japan) |

|
 |
For
immediate assistance, call our Customer Service Hotline
at 800-458-4615 - or
Contact Us to request more information.
|
 |
|
|