Criticare Systems Inc. Products
Home About CSI Services Investor Info Contact Us

503DX miniSpO2t Handheld Oximeter
504DX Portable Pulse Oximeter
506N3 Vital Signs Monitor
506NV3 Vital Signs Monitor with TurboTemp
8100E nGenuity Vital Signs Monitor
8100E1 nGenuity Vital Signs Monitor w/CO2
8100 Poet Plus Vital Signs Monitor
8500 Poet IQ Anesthetic Gas Monitor
8500 Poet IQ2 Anesthetic Gas Monitor
VitalView Central Station
Regulatory Documents
Go to List of Printable Files

Click for Larger Image
Click for Larger Image
 


8500 Poet IQ Anesthetic Gas Monitor
Features & Benefits
Technical Specifications
Catalog / Accessory Information
Request More Information
Technical Specifications Printable File
Download Acrobat Reader



A powerful combination – proprietary CSI vital signs and 5-agent gas analysis technology. Versatile, reliable, and incredibly compact. Designed to operate simply, in less time, and with greater accuracy!

CSI’s new Poet IQ® Gas Monitor, together with the Poet Plus® 8100 Vital Signs Monitor, provides a unique combination of leading edge vital signs technology and anesthesia gas monitoring in a compact, modular system. The Poet IQ automatically identifies and quantifies inspired and expired CO2, N2O, O2, and five anesthetic agents. The system’s reliable performance, ease of use, flexible design, and affordable cost make it the ideal monitoring solution for anesthesia applications in hospitals and surgical centers.

Features and Benefits

 

  • State-of-the-art NDIR technology identifies and measures five anesthetic agent gases: Halothane, Isoflurane, Enflurane, Sevoflurane, and Desflurane.
  • Automatic or manual.
  • Breath-by-breath O2, CO2, and N2O monitoring.
  • Gas flow sampled at 100, 150 and 200 ml/min.
  • Mixed agent identification.
  • Measurement accuracy is not affected by alcohol or ketones.
  • Fast warm-up time ensures full accuracy within minutes.
  • No user calibration required; minimal user interaction.
  • Intuitive, easily configured user interface minimizes training and is ideal for multiple users.
  • Bright, real-time display of numerical values and waveforms provides instant notification of changing patient status.
  • Lightweight, portable design provides flexible workspace options.
Back To Top
Technical Specifications


Gas Monitoring

Method: Sidestream; Non-dispersive infrared (NDIR)
Identified Gases: Halothane, Isoflurane, Enflurane, Desflurane, Sevoflurane, CO2, N2O, Oxygen
Output Data: Inspired and end-tidal gas concentrations; continuous real-time gas concentrations; respiratory rate (elapsed time since last breath); agent identification (primary agent and mixed agents); system information (diagnostic status messages)

Agent Detection
Measurement Range:
Halothane: 0 to 10%
Isoflurane: 0 to 10%
Enflurane: 0 to 10%
Desflurane: 0 to 20%
Sevoflurane: 0 to 10%
CO2: 0 to 12.5%
N2O: 0 to 99%
Oxygen: 0 to 100%

Measurement Accuracy:
Agents: ± (0.1% abs. + 4% reading)
CO2: ± 0.2% abs. or 4% of reading
N2O: ± (1.5% abs. + 4% of reading)
Oxygen: ± 3 vol.% (for 0-90%), ± 4 vol.% (for 91-99%)

Time to Detect Agent: < 15 seconds @ 200 ml/min
Agent Detection Resolution: 0.1 Volume Percent
Mixed Gas Threshold: 0.2 vol. % +10% of total concentrations

Rise Time:
Agents: 450 msec
CO2: 350 msec
N2O: 400 msec
Oxygen: 600 msec


Respiration Rate:
Range: 1 to 60 breaths/minute
Accuracy: ± 2 bpm or 2% of reading

System Features
System Configuration: Modular design with by-directional communication, via cable, to the Poet Plus 8100 vital signs monitor.

Waveform Output:
Halothane, Isoflurane, Enflurane, Desflurane, Sevoflurane, CO2, N2O, O2
Concentration Units: Vol.%, Torr, kPa, mmHg
Flow Rates: 100 ml/min, 150 ml/min, 200 ml/min
Occlusion Clearing: Automatic

Auto Zeroing: Occurs 30 to 60 minutes
Duration: 3.0 to 7.0 seconds
Manual user calibration not required
Temperature stabilized optical assembly

Alarm Characteristics:
EN 475, Adjustable; with audible and visual indications from the vital signs monitor.
Alarm Levels: High, Medium, Low, Informational

Alarm Modes: Adult/Pediatric/Neonate
High and low limit settings for each mode.

Trends: 24 hours of stored data in vital signs monitor with graphical and tabular trends.

Power Requirements
10 to 28 VDC: 9 watts warm-up, 6 watts operational
Receives power from vital signs monitor.

Mechanical
Weight: 6.5 lbs. (2.95 kg.)
Size: 3.8” (H) x 10.4” (W) x 8.2” (D); 9.65 cm (H) x 26.4 cm (W) x 20.8 cm (D)

Environmental
Operating Temperature: 15º to 35º C; 59º to 95º F
Storage Temperature: -5º to 50º C; 23º to 122º F
Operating/ Storage Humidity: 15% to 95%, noncondensing
Altitude: -1,000 to 10,000 ft. (-300m to 3000m)
Type of Protection: Class I Equipment
Degree of Protection: Type CF, Defibrillator-proof
Protection against ingress: Ordinary


Specifications subject to change without notice.

Back To Top

Catalog/Accessory Information

 

GAS MONITORING ACCESSORIES

Sampling Devices
Catalog Number Description
625N Sample Lines (Box of 25)
624 Disposable Nasal Cannula (Box of 10)
628 Divided Nasal Cannula (Box of 10)
616 Endotracheal Adaptor, Straight (Box of 10)
617 Endotracheal Adaptor, Elbow (Box of 10)
938F-NC WaterChek™ 2+ Water Trap (Box of 30)
644 Replacement O2 Cell
655 Scavenging Kit (Exhaust Line & Adaptor)


Calibration Accessories
Catalog Number Description
621 Cal Gas Cylinder (5% CO2, Balance N2)
622 Cal Gas Cylinder (10% CO2, Balance N2)
716 Cal Gas Cylinder (95% O2, Balance CO2)
620 Cal Gas Cylinder (100% N2)
623 Hardware Regulator For Cylinder
613 Regulator Tubing
641 Cal Gas Aerosol (5% CO2, Bal N2)
642 Cal Gas Aerosol (10% CO2, Bal N2)
631 Cal Gas Aerosol (1% Isoflurane, 5% CO2, 60% N2O, Bal N2)
634 Cal Gas Aerosol (1% Enflurane, 5% CO2, 60% N2O, Bal N2)

635

Cal Gas Aerosol (1% Halothane, 5% CO2, 60% N2O, Bal N2)
1367 Cal Gas Aerosol (1% Sevoflurane, 5% CO2, 60% N2O, Bal N2)
1366 Cal Gas Aerosol (4% Desflurane, 5% CO2, 60% N2O, Bal N2)

 

Calibration Kits
Catalog Number Description
612 CO2 only (Non-Anesthetic Agent)
5% CO
2 cylinder, 10% CO2 cylinder, hardware regulator with
tubing, plastic storage case.
715 CO2 and O2 (Non-Anesthetic Agent)
5% CO
2 cylinder, 10% CO2 cylinder, 95% O2 cylinder regulator
with tubing, plastic storage case.
1365 Anesthetic Agent Verification Kit (5 Agent)
One of each five aerosol agents, ISO, ENF, HAL, SEV, DES
as described above, includes plastic regulators with tubing.
909 Power Cord (Domestic US)
910UK Power Cord (United Kingdom)
910INT Power Cord (International)
910 Unterm Power Cord (Unterminated)
603 Japan Power Cord (Japan)

Back To Top

For immediate assistance, call our Customer Service Hotline at 800-458-4615 - or Contact Us to request more information.


Home | About CSI | Products | Services | Investor Info | Contact Us

Criticare Systems, Inc. -- 20925 Crossroads Circle, Waukesha, WI 53186-4054 -- 262.798.8282 -- Copyright ® 2000 Criticare Systems, Inc. All rights reserved